Sensing range max. 5 mm ... 250 mm 1)
Sensing range 35 mm ... 140 mm
1) Object with 90% remission (based on standard white, DIN 5033).
2) Average service life: 100,000 h at TU = +25 °C.
Supply voltage UB 10 V DC ... 30 V DC 1)
1) Limit values when operated in short-circuit protected network: max. 8 A.
2) May not fall below or exceed UV tolerances.
3) Without load.
4) At Uv > 24 V, IA max. = 50 mA.
5) Signal transit time with resistive load.
6) With light/dark ratio 1:1.
7) A = VS connections reverse-polarity protected.
8) B = inputs and output reverse-polarity protected.
9) D = outputs overcurrent and short-circuit protected.
2 PHOTOELECTRIC SENSORS | SICK Product data sheet | 2024-10-24 16:54:43
Subject to change without notice
GTB6-P1211 | G6
MINIATURE PHOTOELECTRIC SENSORS
Ripple ± 10 % 2)
Current consumption 30 mA 3)
Protection class III
Digital output
Type PNP
Switching mode Light/dark switching
Switching mode selector Selectable via light/dark selector
Signal voltage PNP HIGH/LOW VS - (≤ 3 V) / approx. 0 V
Output current Imax. ≤ 100 mA 4)
Response time < 625 µs 5)
Switching frequency 1,000 Hz 6)
Circuit protection A 7)
B 8)
D 9)
1) Limit values when operated in short-circuit protected network: max. 8 A.
2) May not fall below or exceed UV tolerances.
3) Without load.
4) At Uv > 24 V, IA max. = 50 mA.
5) Signal transit time with resistive load.
6) With light/dark ratio 1:1.
7) A = VS connections reverse-polarity protected.
8) B = inputs and output reverse-polarity protected.
9) D = outputs overcurrent and short-circuit protected.